fan_tach_monitor.cfg modified - 07/15/2025 - 05:50:11 PM
This commit is contained in:
parent
dc4afe4a96
commit
40ccae13cf
1 changed files with 45 additions and 0 deletions
|
@ -0,0 +1,45 @@
|
||||||
|
# Monitoring loop. Begins at Klipper start.
|
||||||
|
[delayed_gcode CHECK_ALL_FANS]
|
||||||
|
initial_duration: 1
|
||||||
|
gcode:
|
||||||
|
HOTEND_FAN_CHECK
|
||||||
|
UPDATE_DELAYED_GCODE ID=CHECK_ALL_FANS DURATION=3
|
||||||
|
|
||||||
|
# Change min_rpm and max_consecutive_stops to your desired values.
|
||||||
|
[gcode_macro HOTEND_FAN_CHECK]
|
||||||
|
variable_he_stop_count: 0
|
||||||
|
gcode:
|
||||||
|
{% set min_rpm = 3000|float %}
|
||||||
|
{% set max_consecutive_stops = 3 %}
|
||||||
|
{% set rpm = printer['heater_fan hotend_fan'].rpm|float %}
|
||||||
|
{% set he_target = printer[printer.toolhead.extruder].target|float %}
|
||||||
|
{% set he_temp = printer[printer.toolhead.extruder].temperature|float %}
|
||||||
|
{% set fan_on_temp = printer.configfile.settings['heater_fan hotend_fan'].heater_temp|float %}
|
||||||
|
{% set he_stop_count = printer["gcode_macro HOTEND_FAN_CHECK"].he_stop_count|int %}
|
||||||
|
|
||||||
|
{% if (he_target >= fan_on_temp) and (rpm < min_rpm) and (he_temp >= fan_on_temp) %}
|
||||||
|
SET_GCODE_VARIABLE MACRO=HOTEND_FAN_CHECK VARIABLE=he_stop_count VALUE={he_stop_count + 1}
|
||||||
|
RESPOND PREFIX="HOTEND FAN CHECK:" MSG="Fan stoppage detected ({he_stop_count+1}/{max_consecutive_stops})."
|
||||||
|
M400
|
||||||
|
{% if printer["gcode_macro HOTEND_FAN_CHECK"].he_stop_count|int >= max_consecutive_stops-1 %}
|
||||||
|
FAN_STOPPAGE_ROUTINE
|
||||||
|
{% endif %}
|
||||||
|
{% else %}
|
||||||
|
SET_GCODE_VARIABLE MACRO=HOTEND_FAN_CHECK VARIABLE=he_stop_count VALUE=0
|
||||||
|
{% endif %}
|
||||||
|
|
||||||
|
# Insert the gcode that you want to run when a fan stoppage is detected.
|
||||||
|
# This runs every ~3 seconds until the stop conditions are cleared.
|
||||||
|
[gcode_macro FAN_STOPPAGE_ROUTINE]
|
||||||
|
gcode:
|
||||||
|
# If not already paused
|
||||||
|
{% if printer['pause_resume'].is_paused|int == 0 %}
|
||||||
|
M117 !!FAN STOPPAGE!!
|
||||||
|
M118 FAN STOPPAGE DETECTED. PAUSING...
|
||||||
|
PAUSE
|
||||||
|
# Turn off the hotend.
|
||||||
|
# !! Don't forget to turn your hotend back on before resume. !!
|
||||||
|
# -- If using this guide's pause/resume macros (in useful_macros.html), the hotend will automatically reheat on resume
|
||||||
|
# -- (as long as the hotend is not turned off BEFORE pause is called)
|
||||||
|
SET_HEATER_TEMPERATURE HEATER=extruder TARGET=0
|
||||||
|
{% endif %}
|